SV-F type BlackBus

- Whisker resistant
- Space saving
- Uninterruptible power server expansion
- Secure connection
SV-F type BlackBus
Specialized for powering server racks
Bus duct with safe and reliable connections
KYODO KY-TEC's server power supply Bus duct "BlackBus" is a power distribution method that is simple to install and can be flexibly adapted to the expansion of the server room.
This will enable smarter data centers that were not possible with previous power supply systems.
Product details
PRODUCT SPECIFICATION
Specification.
| Applicable standards | JIS C8364 |
|---|---|
| Protection class | Indoor: IP3X (indoor specification) |
| conductor | Copper and aluminum conductors (electroplated finish) |
| Insulator | Polyester resin molded products |
| Case | Colored steel sheets |
| Standard paint color (Surface Finish) |
Black (Munsell N-2) |
| Grounding | Case grounding method |
| Installation location | indoor |
Rating
| Power distribution method | Three-phase 3-wire/Single-phase 3-wire/Three-phase 4-wire/DC |
|---|---|
| Rated voltage | 600V (AC) 750V (DC) |
| Rated Current | 200A/300A/400A/600A/800A |
Product Features
PRODUCT FEATURES
-

POINT 01Servers can be expanded without power outages
Data centers operate 24 hours a day, 365 days a year, and of course, the power supply cannot be turned off even when relocating or adding servers.
To cope with such situations, BlackBus has a mechanism that allows the branch box to be attached and detached without power interruption. -

POINT 02Safe and secure branch box connection mechanism
- Plug-in hole interlock mechanism
An interlock mechanism is used so that the plug-in hole opens and closes only when the branch box is connected.
The mechanism automatically connects the earth during the process of connecting the branch box, allowing for safe connection work. - Misconnection prevention mechanism
The plug-in hole is equipped with a mechanism to prevent incorrect connection, so the branch box will not be connected in the wrong direction.
- Plug-in hole interlock mechanism
-

POINT 03Plug-in hole
A branch box can be installed for each server rack, allowing for one-to-one visualization of server rack wiring. Because BlackBus itself functions as a distribution board, it eliminates the need for a traditional distribution board, allowing for more effective use of space in the server room.
-

POINT 04Branch box
Customers have a variety of requests regarding how power should be supplied to server racks. We offer products that support a wide range of options, including branch boxes containing multiple circuit breakers, as well as the ability to specify circuit breakers and incorporate power monitoring.
-

POINT 05Perfect Joint System
BlackBus uses PF Joint Clips (200A-400A) and Perfect Bolts (600A and 800A) for conductor connections. The PF Joint Clip is inserted into the connection, and the conductor connection is completed by simply turning the joint pin a quarter turn and pulling it out. The connection cover cannot be attached until all joint pins have been pulled out.
[For details,Perfect Joint SystemSee -
POINT 06Whisker resistant
BlackBus is a whisker-resistant product that uses nickel-plated conductors and a colored steel (black) case.
-

POINT 07E-BD type insulated Bus duct
This is a Bus duct used as a trunk line to supply power to the loads of multiple Black Bus systems.
[For details,E-BD type insulated Bus ductSee
Route overview map
ROUTE OVERVIEW

Comparison with cable wiring
COMPARISON
→ The table can be scrolled to the right
| CV Cable | Server power supply Bus duct BlackBus |
|
|---|---|---|
![]() |
![]() |
|
| Outline |
|
|
| Benefits |
|
|
| Drawbacks |
|
|